Art

ASTM D6760 PDF

This standard is issued under the fixed designation D; the number 1 This test method is under the jurisdiction of ASTM Committee D18 on Soil and. All the Controls products ASTM D standard. Enter now!. ASTM D (Ultrasonic Crosshole Testing).pdf – Download as PDF File .pdf ), Text File .txt) or read online.

Author: Tygogar Samushura
Country: Equatorial Guinea
Language: English (Spanish)
Genre: History
Published (Last): 5 June 2018
Pages: 329
PDF File Size: 11.94 Mb
ePub File Size: 14.14 Mb
ISBN: 509-2-71913-673-6
Downloads: 76611
Price: Free* [*Free Regsitration Required]
Uploader: Tetaxe

Your basket is empty.

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Take the smart route to manage medical device compliance. You may find similar items within these categories by selecting from the choices below:. Historical Version s – view previous versions of standard. Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results. We use cookies to make our website easier to use and to better understand your needs. Agencies that meet the criteria of Practice D are generally considered capable of competent and objective testing and inspection.

Worldwide Standards We can source any standard from anywhere in the world.

Search all products by. Find Similar Items This product falls into the following categories. This method can also be extended to diaphragm walls, barrettes, dams etc. The method astmm not give the exact type of flaw for example, inclusion, honeycombing, lack of cement particles, etc. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program.

  HIPERTEXTO SANTILLANA QUIMICA 2 PDF

These notes and footnotes excluding those in tables and figures shall not be considered axtm requirements of the standard. Testing should therefore be performed as soon as practical in order to avoid qstm issues. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program.

No other units of measurement are included in this standard. Learn more about the cookies we use and how to change your settings. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Active view current version of standard. Please download Chrome or Firefox or view our browser tips. Barrette, Bored pile, Crosshole sonic logging, Crosshole testing, Drilled shaft, Integrity test, Single hole ultrasonic testing, Ultrasonic logging, Ultrasonic testing. How one applies the results obtained using this standard is beyond its scope.

Click to learn more. How one applies the results obtained using this standard is beyond its scope.

The faster, easier way to work with standards. This test can assess to the integrity of the concrete mainly in the area bounded by the access ducts, which means typically inside the reinforcement cage. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard.

The method is limited primarily to testing the concrete between the access ducts and thus gives x6760 information about the concrete outside the reinforcement cage to which the access ducts are attached when d660 tubes are attached to the inside of the reinforcement cage.

This method is most applicable when performed in tubes that are installed during construction. The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. This method can also be extended to diaphragm walls, barrettes, dams etc. Accept and continue Learn more about the cookies we use and how to change your settings.

  ARGENTINISMOS MARTIN CAPARROS PDF

ASTM D, Test equipment Controls

You may experience issues viewing this site in Internet Explorer 9, 10 or This method is most applicable when performed in tubes that are installed during construction.

No other units of measurement are included in this standard. Link to Active This link will always route to the current Active version of the standard. If defects are detected, then further investigations should be made by excavation or coring the concrete as appropriate, or by other testing such as Test Method DD or Dand measures taken to remediate the structure if a defect is confirmed.

Link to Active This link will always route to the current Active version of the standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Since the generated waves travel through the concrete around the access duct, unless a flaw is massive enough and very near to the access duct it may not be detected by this method.

ASTM D6760 – 16

Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. The method sstm not give the exact type of defect for example, inclusion, honeycombing, lack of cement particles, etc. Active view current version of standard Translated Standard: The data are used to confirm adequate concrete quality or identify zones of poor quality.